Technical Specification of Sinewave Home UPS
|
| PARAMETERS |
UNIT |
ELEGANT SERIES |
| System rating (Name Plate) |
VA |
1700 |
| Operating DC voltage |
V |
12 |
| Technology Based |
|
DSP Microcontroller Based |
| Output voltage on inverter mode |
Vac |
220V ± 10V |
| Output phase |
|
Single Phase |
| Output Frequency on Inverter |
Hz |
50Hz ± 0.1Hz |
| Output voltage regulation |
% |
< 5 % |
| Output THD (v) at linear load |
% |
< 5 % |
| Creast Factor |
|
03:01 |
| Cooling Fan ON at temp |
°C |
55 °C |
| Cooling Fan Off at temp |
°C |
50 °C |
| Battery low voltage alarm per battery |
Vdc |
10.8V |
| Battery low voltage cut per battery |
Vdc |
10.5V |
| Max Battery charging voltage current by grid per battery |
Vdc |
14.4V ± 0.3V |
| Max Battery charging current by grid |
Adc |
Up To 16Amp |
| Input Voltage Range (Inv Mode) |
Vac |
100-290V ± 10V |
| Input Voltage Range (UPS Mode) |
|
180-260 ± 10V |
| Input current at no load at Nominal Battery voltage |
Adc |
<1.5A, DC |
| Noise @ 1 meter |
dB |
< 40 db |
| Protections |
|
Short Circuit, Battery Overvoltage, Battery Lowvoltage, Battery Deep Discharge, Over Temp.(Auto Recovery) |
| LCD Display parameters ( Only in Elegant Series ) |
|
Mains Voltage, Output Voltage, Battery Charging, Battery Charged, And All The Faults |
| Indication LEDs |
|
Mains On, Charging On, Ups On, Battery Low, Overload |
| Changeover time from inverter to mains in UPS mode |
ms |
<10 ms |
| Changeover time from inverter to mains in Normal mode |
ms |
<10 ms |
| Changeover time from mains to inverter in UPS mode |
ms |
<10 ms |
| Changeover time from mains to inverter in Normal mode |
ms |
<20 ms |
| Input Protection |
|
Push to reset Circuit breaker |
| Mode Slection |
|
UPS/Inverter, Charging Voltage Amp HI/LO |
| Weight and Dimension |
| System rating (Name Plate) |
VA |
1700 |
| Packaging Box Dimension (LxWxH) |
MM |
360*340*180 |
| Net Weight |
kG |
12,950Kg |
| Gross Weight |
kG |
13,870Kg |