Diesel Generator Set 125 kVA

Overview of PRODUCT​

125 KVA, Three Phase, 415 Volt, 50 Hz, 0.8 P.F.
POWER Engineering India Pvt Ltd Make Silent Water Cooled Diesel Generator Set Model No VE-125 comprising of Eicher engine model Eicher-E694TCI. 6 No of Cylinders Engines developing 156 HP, STAMFORD alternator rated at 125 KVA, 415 Volt.

Fuel Consumption at 90% Load = 16 Liters Per Hours

EICHER POWERES GENSET TECHNICAL SPECIFICATION

Genset Model   VE-125
Genset Rating KVA / kWe 125 / 100
Power Factor lagging 0.8
Engine Rated Power HP 156
Cooling System   Liquid Cooled
Current Amp Amps 174 A
ENGINE TECHNICAL DETAILS 
Engine Make   EICHER
Engine Model   EE694TCI
No. of Cylinders No. 6 – inLine
Nature of Aspiration   Turbocharged Intercooled
Displacement Liters 5.7
Compression Ratio   17.5:01
Fuel   High Speed Diesel
Bore MM 100
Stroke MM 120
Electric System Volt 12 V DC
Total Coolant Capacity Liters 21.5
Lube Oil Consumption % F. Cons 0.1
Lube Oil System Capacity Liters 23.8
Lub. Oil change Period Hours 500
Lube Oil Standard   15W40CI Standard
Type of Governor Type Mechanical / Electronic
Class of Governing   Calss – A1
Battery Capacity AH 135AH
ALTENATOR TECHNICAL DETAILS 
Alternator Make   STAMFORD
Alternator Type   SELF REGULATED/SELF EXCITED/BRUSHLESS
Type of Insulation   IP 23, Class H
No. of Phase / Voltage Volt 415 Volt Three Phase
Maximum Unbalanced Load Phasewise % less than or equal to 25%
Voltage regulation % ±1 Percentage
Frequency Hz 50 Hz
CONTROL PANEL TECHNICAL DETAILS 
Control Panel Model   MANUAL (Standard) Panel  With DSC Controller DSC4520
Type of Panel   MANUAL (Standard) / Auto Mains Failure (Optional)
Make of Controller   Deep-sea/Equivalent Reputed make
Location   Mounted Inside Acoustic Enclosure
Type of MCB/MCCB 3P/4P 3P MCCB
Current Breaking Capacity Amps 200
Metering of Alternator   Frequency, Line to Line Voltage and Line to Neutral Voltage, Current AMP, kVA 
Metering of ƒEngine    Engine Running Hours, Engine Temperature, Oil Pressure, Starting Battery Voltage 
Protection   High/Low Coolant Temperature, Low Lube Oil Pressure, Battery Over Voltage / Under Voltage / Weak Volts, Fail to Start, Sensor Failure, Cranking Lockout, Low Fuel Level, Over Voltage / Under Voltage, Frequency
ACOUSTIC ENCLOSURE TECHNICAL DETAILS 
Type of Canopy   Outdoor Type, Ready to use – (CPCB-II Complaint)
Noise Level dB 75 dB at 1 Meter
Fuel Tank Capacity Liters 200 Liters
Fuel Tank Location   Mounted at base Inside Acoustic Enclosure
Engine & Alternator Mounting   Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.
Inside Acoustic Enclosure
Acoustic Enclosure Size in “mm” L 3400
W 1200
H 1500
Genset With Acoustic Enclosure Weight Kgs 2200
# Power rating as per standard reference condition as per –BS 5514 / ISO 3046 / ISO 8528/ IS 10002.
# Fuel consumption data is based on diesel having specific gravity of 0.85. Fuel consumption tolerance is +5%
# All technical specifications are subject to change due to continuous product development without prior notice.
# Diesel Generators are manufactured by authorized OEA of VE Commercial Vehicles Ltd. in different design and color.